Michelson interferometer with wear free and reliability of 10 year guaranty, with cube- corner mirror resist mechanical and temperature vibration
Higher stability of optical system is designed with gold mirror improve reflectivity by > 5 % than traditional aluminum mirror.
Super sensitivity and reliable temperature controlled DTGS detectors
Reliable performance of solid laser life up to 10 years
Vacuum cooling ceramic IR light source with high performance
Powerful software functions for include batch operation and analysis, integrated automatic acquisition function, online in-field monitor.
Items |
Standard Specification |
Extendable specification |
Spectral Resolution |
≤0.4 cm-1 |
Upgrade to <0.25 cm-1 |
Spectral Range |
8000-350cm-1 |
12800-4000cm-1 |
IR source |
Vacuum-cooling ceramic light source |
Tungsten lamp |
Laser |
Solid laser |
- |
Beam splitters |
KBr |
Quartz, CaF2, ZnSe,Ge |
Detectors |
Temperature controlled DTGS detector |
Optional: LN cooled MCT detector, Semi-conductor cooled MCT detector, LN cooled InSb detector, LN cooled Ge detector and semi-conductor InGaAs detector |
Sample Compartment |
Transmission sample compartment |
Optional: IR Emission interface, External sample compartment, External sealed UHV compartment |
Interferometer |
Cube-corner mirror Michelson interferometer, wear free fit to many field measure can resist to mechanical and temperature vibration |
|
Wavenumber Accuracy |
Better than 0.01 cm-1 |
|
Wavenumber Precision |
Better than 0.01cm-1 |
|
Transmission Precision |
Better than 0. 1%T |
|
SNR |
≥40,000:1 1 min sample measurement, 4 cm- 1, peak-to-peak |
|
Dimension |
685×415×223mm |
Protein conformation and quantification Quantification for Active Pharmaceutical Ingredients and excipient in water solution
Characterization for the volatility and stability of medicine combined with TGA module
Detection and Characterization for the volatility and decomposition combined with TGA module Monitoring reaction process in lab combined with MIR fiber
Detection and Characterization for the Ultra-Thin film and mono-layer film Characterization for the erosion process
Detection of Emissivity of building materials Evaluation for Optical material such as Infrared windows and mirrors
Different non- metal film measure Quality control medium carbon / oxygen impurity identification
Soil fertility and organic evaluation Soil properties research
Michelson interferometer with wear free and reliability of 10 year guaranty, with cube- corner mirror resist mechanical and temperature vibration
Higher stability of optical system is designed with gold mirror improve reflectivity by > 5 % than traditional aluminum mirror.
Super sensitivity and reliable temperature controlled DTGS detectors
Reliable performance of solid laser life up to 10 years
Vacuum cooling ceramic IR light source with high performance
Powerful software functions for include batch operation and analysis, integrated automatic acquisition function, online in-field monitor.
Items |
Standard Specification |
Extendable specification |
Spectral Resolution |
≤0.4 cm-1 |
Upgrade to <0.25 cm-1 |
Spectral Range |
8000-350cm-1 |
12800-4000cm-1 |
IR source |
Vacuum-cooling ceramic light source |
Tungsten lamp |
Laser |
Solid laser |
- |
Beam splitters |
KBr |
Quartz, CaF2, ZnSe,Ge |
Detectors |
Temperature controlled DTGS detector |
Optional: LN cooled MCT detector, Semi-conductor cooled MCT detector, LN cooled InSb detector, LN cooled Ge detector and semi-conductor InGaAs detector |
Sample Compartment |
Transmission sample compartment |
Optional: IR Emission interface, External sample compartment, External sealed UHV compartment |
Interferometer |
Cube-corner mirror Michelson interferometer, wear free fit to many field measure can resist to mechanical and temperature vibration |
|
Wavenumber Accuracy |
Better than 0.01 cm-1 |
|
Wavenumber Precision |
Better than 0.01cm-1 |
|
Transmission Precision |
Better than 0. 1%T |
|
SNR |
≥40,000:1 1 min sample measurement, 4 cm- 1, peak-to-peak |
|
Dimension |
685×415×223mm |
Protein conformation and quantification Quantification for Active Pharmaceutical Ingredients and excipient in water solution
Characterization for the volatility and stability of medicine combined with TGA module
Detection and Characterization for the volatility and decomposition combined with TGA module Monitoring reaction process in lab combined with MIR fiber
Detection and Characterization for the Ultra-Thin film and mono-layer film Characterization for the erosion process
Detection of Emissivity of building materials Evaluation for Optical material such as Infrared windows and mirrors
Different non- metal film measure Quality control medium carbon / oxygen impurity identification
Soil fertility and organic evaluation Soil properties research