Click: Enter standby(sleep) mode
Double click: light intensity lock or unlock
Rotation: Adjust brightness
Press + clockwise rotate: Switch to the transmitted light source
Press + contrarotate: Switch to the fluorescent light source
Press 3 seconds: Set the time of turning off the light after leaving
3. Display microscope working mode.
The LCD screen in the front of the microscope can display the working mode of the microscope, including magnification, light intensity, sleep mode and so on.
Hoffman Modulation Phase Contrast. With slant light, Hoffman phase contrast changes phase gradient into light intensity variety, it can be used to oSTMerve unstained cells and living cells. Giving 3D effect for thick samples, it can greatly reduce the halo in thick specimens.
Fly-eye lens and Kohler illumination have provided a uniform and bright field of view, which is benefit to get high definition images and perfect details. Compared with traditional mercury bulb, the LED lamp has much longer working life, it saves money and has greatly improved the working efficiency. The problems of preheating, cooling and high temperature of mercury lamp has also been solved.
2. Suitable for a variety of fluorescent dyes.
The LED fluorescent attachment has equipped with 3 fluorescent filter blocks, it can be applied to a wide range of dyes and capture clear high contrast fluorescence images.
3. Light shutter on transmitted is available to provide a better fluorescent effect.
The light shutter can effectively block the external light, increase the contrast of the fluorescent image and provide a high quality fluorescent image. When need phase contrast oSTMervation, the light shutter is very convenient to be removed from the light path, avoiding influence on the quality of phase contrast
Item |
Specification |
STM-2094C |
STM-2094CF |
|
Optical System |
NIS 60 Infinite Optical System, Tube length 200mm |
Standard |
Standard |
|
Viewing Head |
Seidentopf Tilting Binocular Head, adjustable 0-35° inclined, Interpupillary Distance 48-75mm, Left side camera port, Light distribution: 100: 0 (100% for eyepiece), 0:100 (100% for camera), Eyepiece Tube Diameter 30mm |
Standard |
Standard |
|
Eyepiece |
SW10×/ 22mm |
Standard |
Standard |
|
WF15×/ 16mm |
Optional |
Optional |
||
WF20×/ 12mm |
Optional |
Optional |
||
Objective (Parfocal distance 60mm, M25×0.75) |
NIS60 Infinite LWD Plan Achromatic Objective |
4×/0.1, WD=30mm |
Standard |
Optional |
10×/0.25, WD=10.2mm |
Optional |
Optional |
||
20×/0.40, WD=12mm |
Optional |
Optional |
||
40×/0.60, WD=2.2mm |
Optional |
Optional |
||
NIS60 Infinite LWD Plan Phase Contrast Achromatic Objective |
PH4×/0.1, WD=30mm |
Optional |
Optional |
|
PH10×/0.25, WD=10.2mm |
Standard |
Optional |
||
PH20×/0.40, WD=12mm |
Standard |
Optional |
||
PH40×/0.60, WD=2.2mm |
Standard |
Optional |
||
NIS60 Infinite LWD Plan Semi-APO Fluorescent Objective |
4×/0.13, WD=17mm, cover glass=- |
Optional |
Standard |
|
10×/0.3, WD=7.4mm, cover glass=1.2mm |
Optional |
Standard |
||
20×/0.45, WD=8mm, cover glass=1.2mm |
Optional |
Standard |
||
40×/0.60, WD=3.3mm, cover glass=1.2mm |
Optional |
Standard |
||
NIS60 Infinite LWD Plan Semi-APO Phase Contrast Objective |
4×/0.13, WD=17.78mm, cover glass=- |
Optional |
Optional |
|
10×/0.3, WD=7.4mm, cover glass=1.2mm |
Optional |
Optional |
||
20×/0.45, WD=7.5-8.8mm, cover glass=1.2mm |
Optional |
Optional |
||
40×/0.60, WD=3-3.4mm, cover glass=1.2mm |
Optional |
Optional |
||
Nosepiece |
Coded Quintuple Nosepiece |
Standard |
Standard |
|
Condenser |
Long Working Distance Condenser, N.A. 0.3, Working Distance 75mm (with condenser), 187mm (without condenser) |
Standard |
Standard |
|
Telescope |
Centering Telescope: used to adjust the center of phase annulus |
Standard |
Standard |
|
Phase Annulus |
10×-20×-40× Phase Annulus Plate (center adjustable) |
Standard |
Standard |
|
4× Phase Annulus Plate |
Optional |
Optional |
||
Stage |
Stage 170 (X)×250(Y) mm with glass insert plate (diameter 110mm) |
Standard |
Standard |
|
Attachable Mechanical Stage, X-Y Coaxial Control, Moving Rang: 128mm×80mm, accept 5 types of petri-dish holders, well plates and stage clips |
Standard |
Standard |
||
Auxiliary stage 70mm×180mm, used to extend the stage |
Optional |
Standard |
||
Universal Holder: used for Terasaki plate, glass slide and Φ35-65mm petri dishes |
Standard |
Standard |
||
Terasaki Holder: used for Φ35mm Petri Dish Holder and Φ65mm petri dishes |
Optional |
Optional |
||
Glass Slide and Petri Dish Holder Φ54mm |
Optional |
Optional |
||
Glass Slide and Petri Dish Holder Φ65mm |
Optional |
Optional |
||
Petri Dish Holder Φ35mm |
Optional |
Optional |
||
Petri Dish Holder Φ90mm |
Optional |
Optional |
||
Focusing |
Coaxial Coarse and Fine Adjustment, tension adjustment, Fine Division 0.001mm, Fine stroke 0.2mm per rotation, Coarse stroke 37.5mm per rotation. Moving Range: up 7mm, down 1.5mm; Without limitation can up to 18.5mm |
Standard |
Standard |
|
Transmitted Illumination |
3W S-LED Koehler illumination, Brightness Adjustable |
Standard |
Standard |
|
EPI-Fluorescent Attachment |
LED illuminator, built-in Fly-eye lens, can be configured with up to 3 different fluorescence blocks; with B, G, U fluorescent filters |
Optional |
Standard |
|
B1, V, R fluorescent filters |
Optional |
Optional |
||
Hoffman phase contrast |
Hoffman Condenser with 10×, 20×, 40× insert plate, centering telescope and special objective 10×, 20×, 40× |
Optional |
Optional |
|
3D Emboss Contrast |
Main emboss contrast plate with 10×-20×-40× will be inserted into condenser |
Optional |
Optional |
|
Auxiliary emboss contrast plate will be inserted into slot which is near viewing head |
Optional |
Optional |
||
C-mount Adapter |
0.5× C-mount Adapter (focus adjustable) |
Optional |
Optional |
|
1× C-mount Adapter (focus adjustable) |
Optional |
Optional |
||
Other Accessories |
ECO function: will turn off after 15 minutes if no user |
Standard |
Standard |
|
Warm stage |
Optional |
Optional |
||
Light shutter, can be used to block the external light |
Standard |
Standard |
||
Dust cover |
Standard |
Standard |
||
Power Supply |
AC 100-240V, 50/60Hz |
Standard |
Standard |
|
Fuse |
T250V500mA |
Standard |
Standard |
|
Packing |
2cartons/set, Packing Size: 47cm×37cm×39cm, 69cm×39cm×64cm, Gross Weight: 20kgs, Net Weight: 18kgs |
Standard |
Standard |
STM-2094C inverted microscope is used by medical and health units, universities, research institutes for oSTMervations of micro-organisms, cells, bacteria and tissue cultivation. They can be used for continuous oSTMervation of process of cells, bacteria grow and divide in the culture medium. Videos and images can be taken during the process. These microscopes are widely used in cytology, parasitology, oncology, immunology, genetic engineering, industrial microbiology, botany and other fields
Click: Enter standby(sleep) mode
Double click: light intensity lock or unlock
Rotation: Adjust brightness
Press + clockwise rotate: Switch to the transmitted light source
Press + contrarotate: Switch to the fluorescent light source
Press 3 seconds: Set the time of turning off the light after leaving
3. Display microscope working mode.
The LCD screen in the front of the microscope can display the working mode of the microscope, including magnification, light intensity, sleep mode and so on.
Hoffman Modulation Phase Contrast. With slant light, Hoffman phase contrast changes phase gradient into light intensity variety, it can be used to oSTMerve unstained cells and living cells. Giving 3D effect for thick samples, it can greatly reduce the halo in thick specimens.
Fly-eye lens and Kohler illumination have provided a uniform and bright field of view, which is benefit to get high definition images and perfect details. Compared with traditional mercury bulb, the LED lamp has much longer working life, it saves money and has greatly improved the working efficiency. The problems of preheating, cooling and high temperature of mercury lamp has also been solved.
2. Suitable for a variety of fluorescent dyes.
The LED fluorescent attachment has equipped with 3 fluorescent filter blocks, it can be applied to a wide range of dyes and capture clear high contrast fluorescence images.
3. Light shutter on transmitted is available to provide a better fluorescent effect.
The light shutter can effectively block the external light, increase the contrast of the fluorescent image and provide a high quality fluorescent image. When need phase contrast oSTMervation, the light shutter is very convenient to be removed from the light path, avoiding influence on the quality of phase contrast
Item |
Specification |
STM-2094C |
STM-2094CF |
|
Optical System |
NIS 60 Infinite Optical System, Tube length 200mm |
Standard |
Standard |
|
Viewing Head |
Seidentopf Tilting Binocular Head, adjustable 0-35° inclined, Interpupillary Distance 48-75mm, Left side camera port, Light distribution: 100: 0 (100% for eyepiece), 0:100 (100% for camera), Eyepiece Tube Diameter 30mm |
Standard |
Standard |
|
Eyepiece |
SW10×/ 22mm |
Standard |
Standard |
|
WF15×/ 16mm |
Optional |
Optional |
||
WF20×/ 12mm |
Optional |
Optional |
||
Objective (Parfocal distance 60mm, M25×0.75) |
NIS60 Infinite LWD Plan Achromatic Objective |
4×/0.1, WD=30mm |
Standard |
Optional |
10×/0.25, WD=10.2mm |
Optional |
Optional |
||
20×/0.40, WD=12mm |
Optional |
Optional |
||
40×/0.60, WD=2.2mm |
Optional |
Optional |
||
NIS60 Infinite LWD Plan Phase Contrast Achromatic Objective |
PH4×/0.1, WD=30mm |
Optional |
Optional |
|
PH10×/0.25, WD=10.2mm |
Standard |
Optional |
||
PH20×/0.40, WD=12mm |
Standard |
Optional |
||
PH40×/0.60, WD=2.2mm |
Standard |
Optional |
||
NIS60 Infinite LWD Plan Semi-APO Fluorescent Objective |
4×/0.13, WD=17mm, cover glass=- |
Optional |
Standard |
|
10×/0.3, WD=7.4mm, cover glass=1.2mm |
Optional |
Standard |
||
20×/0.45, WD=8mm, cover glass=1.2mm |
Optional |
Standard |
||
40×/0.60, WD=3.3mm, cover glass=1.2mm |
Optional |
Standard |
||
NIS60 Infinite LWD Plan Semi-APO Phase Contrast Objective |
4×/0.13, WD=17.78mm, cover glass=- |
Optional |
Optional |
|
10×/0.3, WD=7.4mm, cover glass=1.2mm |
Optional |
Optional |
||
20×/0.45, WD=7.5-8.8mm, cover glass=1.2mm |
Optional |
Optional |
||
40×/0.60, WD=3-3.4mm, cover glass=1.2mm |
Optional |
Optional |
||
Nosepiece |
Coded Quintuple Nosepiece |
Standard |
Standard |
|
Condenser |
Long Working Distance Condenser, N.A. 0.3, Working Distance 75mm (with condenser), 187mm (without condenser) |
Standard |
Standard |
|
Telescope |
Centering Telescope: used to adjust the center of phase annulus |
Standard |
Standard |
|
Phase Annulus |
10×-20×-40× Phase Annulus Plate (center adjustable) |
Standard |
Standard |
|
4× Phase Annulus Plate |
Optional |
Optional |
||
Stage |
Stage 170 (X)×250(Y) mm with glass insert plate (diameter 110mm) |
Standard |
Standard |
|
Attachable Mechanical Stage, X-Y Coaxial Control, Moving Rang: 128mm×80mm, accept 5 types of petri-dish holders, well plates and stage clips |
Standard |
Standard |
||
Auxiliary stage 70mm×180mm, used to extend the stage |
Optional |
Standard |
||
Universal Holder: used for Terasaki plate, glass slide and Φ35-65mm petri dishes |
Standard |
Standard |
||
Terasaki Holder: used for Φ35mm Petri Dish Holder and Φ65mm petri dishes |
Optional |
Optional |
||
Glass Slide and Petri Dish Holder Φ54mm |
Optional |
Optional |
||
Glass Slide and Petri Dish Holder Φ65mm |
Optional |
Optional |
||
Petri Dish Holder Φ35mm |
Optional |
Optional |
||
Petri Dish Holder Φ90mm |
Optional |
Optional |
||
Focusing |
Coaxial Coarse and Fine Adjustment, tension adjustment, Fine Division 0.001mm, Fine stroke 0.2mm per rotation, Coarse stroke 37.5mm per rotation. Moving Range: up 7mm, down 1.5mm; Without limitation can up to 18.5mm |
Standard |
Standard |
|
Transmitted Illumination |
3W S-LED Koehler illumination, Brightness Adjustable |
Standard |
Standard |
|
EPI-Fluorescent Attachment |
LED illuminator, built-in Fly-eye lens, can be configured with up to 3 different fluorescence blocks; with B, G, U fluorescent filters |
Optional |
Standard |
|
B1, V, R fluorescent filters |
Optional |
Optional |
||
Hoffman phase contrast |
Hoffman Condenser with 10×, 20×, 40× insert plate, centering telescope and special objective 10×, 20×, 40× |
Optional |
Optional |
|
3D Emboss Contrast |
Main emboss contrast plate with 10×-20×-40× will be inserted into condenser |
Optional |
Optional |
|
Auxiliary emboss contrast plate will be inserted into slot which is near viewing head |
Optional |
Optional |
||
C-mount Adapter |
0.5× C-mount Adapter (focus adjustable) |
Optional |
Optional |
|
1× C-mount Adapter (focus adjustable) |
Optional |
Optional |
||
Other Accessories |
ECO function: will turn off after 15 minutes if no user |
Standard |
Standard |
|
Warm stage |
Optional |
Optional |
||
Light shutter, can be used to block the external light |
Standard |
Standard |
||
Dust cover |
Standard |
Standard |
||
Power Supply |
AC 100-240V, 50/60Hz |
Standard |
Standard |
|
Fuse |
T250V500mA |
Standard |
Standard |
|
Packing |
2cartons/set, Packing Size: 47cm×37cm×39cm, 69cm×39cm×64cm, Gross Weight: 20kgs, Net Weight: 18kgs |
Standard |
Standard |
STM-2094C inverted microscope is used by medical and health units, universities, research institutes for oSTMervations of micro-organisms, cells, bacteria and tissue cultivation. They can be used for continuous oSTMervation of process of cells, bacteria grow and divide in the culture medium. Videos and images can be taken during the process. These microscopes are widely used in cytology, parasitology, oncology, immunology, genetic engineering, industrial microbiology, botany and other fields