SCP-1000
Smart Cap, Liquid Level & Temp Monitor

Stalwart SCP-1000 is real-time temperature display. Even liquid level sensor fail, user could know low LN2 level from temperature increase. When temperature exceed the setting temperature, it will alarm.

Stalwart Smart Cap realizes both liquid nitrogen level and temperature monitor on a compact designed plug. This is a real user-friendly device, which doesn't need to connect any extra wires, sensors, and even power supply. The whole system is built based on unique STALWART ultra-low power consumption technology. STALWART provide optional relay to connect Wi-Fi for data transfer. User can check temperature and liquid level on line.

Quantity :
  • Features
  • Specifications
  • Literature

Features

  • Real-time liquid nitrogen level display. No need to remove plug and use liquid level meter to check liquid level.
  • Real-time temperature display. Even liquid level sensor fail, user could know low LN2 level from temperature increase. Provide dual-protection for samples.
  • Optional relay to connect Wi-Fi for data transfer. User can check temperature and liquid level on line.
  • Low power consumption technology and long life time for battery.
  • Can be used for different size of containers with 125mm and 216m neck diameter.

Specifications

Model

SCP-1000

Temperature Range

-200 ~200℃

Temperature Accuracy

±0.1℃

Temperature Sensor

PT-1000

Liquid Level Range

160~570mm

Liquid Level Tolerance

±10mm

Power Supply

Built-in Nickel Battery

Relay (Optional)

Wi-Fi connection, data transfer, checking and storage

 

Literature

SCP-1000 Brochure

Features

  • Real-time liquid nitrogen level display. No need to remove plug and use liquid level meter to check liquid level.
  • Real-time temperature display. Even liquid level sensor fail, user could know low LN2 level from temperature increase. Provide dual-protection for samples.
  • Optional relay to connect Wi-Fi for data transfer. User can check temperature and liquid level on line.
  • Low power consumption technology and long life time for battery.
  • Can be used for different size of containers with 125mm and 216m neck diameter.

Specifications

Model

SCP-1000

Temperature Range

-200 ~200℃

Temperature Accuracy

±0.1℃

Temperature Sensor

PT-1000

Liquid Level Range

160~570mm

Liquid Level Tolerance

±10mm

Power Supply

Built-in Nickel Battery

Relay (Optional)

Wi-Fi connection, data transfer, checking and storage

 

Literature

SCP-1000 Brochure

Related Products