Model |
SFP-450 |
SFP-440 |
SFP-432 |
SFP-431 |
SFP-430 |
SFP-410 |
SFP-410 |
|||
Display |
7-inch color touch screen |
|||||||||
Display Results |
Concentration value/Energy |
|||||||||
Reading Range |
0.000~999.9/0~65535 |
|||||||||
Testable |
K, Na, Li, Ca, Ba |
K, Na, Li, Ca |
K, Na, Ba |
K, Na, Ca |
K, Na, Li |
K, Na |
K, Na |
|||
Channel Qty |
5 |
4 |
3 |
3 |
3 |
2 |
2 |
|||
Range ppm |
K |
0-100 |
0-100 |
0-100 |
0-100 |
0-100 |
0-100 |
0-100 |
||
Na |
0-160 |
0-160 |
0-160 |
0-160 |
0-160 |
0-160 |
0-160 |
|||
Li |
0-100 |
0-100 |
—— |
—— |
0-100 |
—— |
—— |
|||
Ca |
0-1000 |
0-1000 |
—— |
0-1000 |
—— |
—— |
—— |
|||
Ba |
0-3000 |
—— |
0-3000 |
—— |
—— |
—— |
—— |
|||
Detection Limit ppm |
K |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
||
Na |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
|||
Li |
0.1 |
≤0.015 |
—— |
—— |
≤0.015 |
—— |
—— |
|||
Ca |
2 |
2 |
—— |
2 |
—— |
—— |
—— |
|||
Ba |
6 |
—— |
6 |
—— |
—— |
—— |
—— |
|||
Linear Error |
K |
0.195 |
0.195 |
0.195 |
0.195 |
0.195 |
0.195 |
0.195 |
||
Na |
0.69 |
0.69 |
0.69 |
0.69 |
0.69 |
0.69 |
0.69 |
|||
Li |
0.15 |
0.15 |
—— |
—— |
0.15 |
—— |
—— |
|||
Ca |
3 |
3 |
—— |
3 |
—— |
—— |
—— |
|||
Ba |
9 |
—— |
9 |
—— |
—— |
—— |
—— |
|||
Response Time |
<8S |
|||||||||
Sample Uptake |
<6ml/min |
|||||||||
Stability |
<3% drift over 15s when continuous sampling |
|||||||||
Reproducibility |
<3% coefficient of variation for 7 consecutive samples |
|||||||||
Curve Graph |
Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
|||
Printer |
Optional |
Optional |
Optional |
Optional |
Optional |
Yes |
Optional |
|||
PC Connection |
Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
|||
Output |
USB port |
|||||||||
Power |
AC 220V/50Hz or AC 110V/60Hz |
|||||||||
Model |
SFP-450 |
SFP-440 |
SFP-432 |
SFP-431 |
SFP-430 |
SFP-410 |
SFP-410 |
|||
Display |
7-inch color touch screen |
|||||||||
Display Results |
Concentration value/Energy |
|||||||||
Reading Range |
0.000~999.9/0~65535 |
|||||||||
Testable |
K, Na, Li, Ca, Ba |
K, Na, Li, Ca |
K, Na, Ba |
K, Na, Ca |
K, Na, Li |
K, Na |
K, Na |
|||
Channel Qty |
5 |
4 |
3 |
3 |
3 |
2 |
2 |
|||
Range ppm |
K |
0-100 |
0-100 |
0-100 |
0-100 |
0-100 |
0-100 |
0-100 |
||
Na |
0-160 |
0-160 |
0-160 |
0-160 |
0-160 |
0-160 |
0-160 |
|||
Li |
0-100 |
0-100 |
—— |
—— |
0-100 |
—— |
—— |
|||
Ca |
0-1000 |
0-1000 |
—— |
0-1000 |
—— |
—— |
—— |
|||
Ba |
0-3000 |
—— |
0-3000 |
—— |
—— |
—— |
—— |
|||
Detection Limit ppm |
K |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
||
Na |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
|||
Li |
0.1 |
≤0.015 |
—— |
—— |
≤0.015 |
—— |
—— |
|||
Ca |
2 |
2 |
—— |
2 |
—— |
—— |
—— |
|||
Ba |
6 |
—— |
6 |
—— |
—— |
—— |
—— |
|||
Linear Error |
K |
0.195 |
0.195 |
0.195 |
0.195 |
0.195 |
0.195 |
0.195 |
||
Na |
0.69 |
0.69 |
0.69 |
0.69 |
0.69 |
0.69 |
0.69 |
|||
Li |
0.15 |
0.15 |
—— |
—— |
0.15 |
—— |
—— |
|||
Ca |
3 |
3 |
—— |
3 |
—— |
—— |
—— |
|||
Ba |
9 |
—— |
9 |
—— |
—— |
—— |
—— |
|||
Response Time |
<8S |
|||||||||
Sample Uptake |
<6ml/min |
|||||||||
Stability |
<3% drift over 15s when continuous sampling |
|||||||||
Reproducibility |
<3% coefficient of variation for 7 consecutive samples |
|||||||||
Curve Graph |
Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
|||
Printer |
Optional |
Optional |
Optional |
Optional |
Optional |
Yes |
Optional |
|||
PC Connection |
Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
|||
Output |
USB port |
|||||||||
Power |
AC 220V/50Hz or AC 110V/60Hz |
|||||||||