A Smart Freezer
A Green Freezer
A User-Friendly Freezer
Model | STF-408E | |
Technical Data | Type | Upright |
Capacity (L/cu ft) | 408/14.41 | |
Inner doors | 2 pcs, SUS304 forming door | |
Shelves | 3 pcs, SUS304 | |
Inner chamber material | SUS304 | |
Cooling type | Direct cooling | |
Refrigerant |
Hydrocarbon, CFC Free, Non greehouse |
|
Noise level (dB) | 50 | |
Temperature | Ambient temperature(ºC) | 10~32ºC |
Temperature range (ºC) | -40~-86ºC | |
Cooling & Controller | Cooling | Two compressors |
System | cascade system | |
Compressor Brand | SECOP | |
Sensor | PT100 | |
Controller | Microprocessor | |
Display & Control | 7" Touch Screen | |
Electronic parameter
|
Voltage/Frequency | 220~240V 50/60Hz 110V 60Hz |
Power (W) | 845 | |
Power Consumption (kWh/24h) | 11.6 | |
Vials load | 2ml Vials (pcs) | 28800 |
Size & Weight | Internal (W*D*H) mm | 606×575×1180 |
External (W*D*H) mm | 900×940×1940 | |
Packing (W*D*H) mm | 950×960×2110 | |
Net/Gross weight (kg) | 215/245 | |
Alarm System | High/low temperature | √ |
Power off failure | √ | |
Abnormal voltage | √ | |
Sensor error | √ | |
Filter screen check | √ | |
Controller failure | √ | |
Low battery | √ | |
Condenser malfunction | √ | |
High ambient temperature | √ | |
Door ajar | √ | |
Accessories | Caster | 4 |
Test hole/Diameter | 1/25mm | |
Remote alarm contact | √ | |
USB Port | Y | |
RS232/485 port | Optional | |
Temperature recorder | Optional | |
Freezer racks | Optional | |
CO2 backup system | Optional | |
LN2 backup system | Optional |
The -86℃ ULT freezer is specially designed for a stable ultra low temperature storage condition, to store germs, erythrocytes, leucocytes, viruses and many other biological materials. Installations can be found in research institutes, pharmacy industry, clinical labs, blood banks and laboratories in electronic & chemical plants.
A Smart Freezer
A Green Freezer
A User-Friendly Freezer
Model | STF-408E | |
Technical Data | Type | Upright |
Capacity (L/cu ft) | 408/14.41 | |
Inner doors | 2 pcs, SUS304 forming door | |
Shelves | 3 pcs, SUS304 | |
Inner chamber material | SUS304 | |
Cooling type | Direct cooling | |
Refrigerant |
Hydrocarbon, CFC Free, Non greehouse |
|
Noise level (dB) | 50 | |
Temperature | Ambient temperature(ºC) | 10~32ºC |
Temperature range (ºC) | -40~-86ºC | |
Cooling & Controller | Cooling | Two compressors |
System | cascade system | |
Compressor Brand | SECOP | |
Sensor | PT100 | |
Controller | Microprocessor | |
Display & Control | 7" Touch Screen | |
Electronic parameter
|
Voltage/Frequency | 220~240V 50/60Hz 110V 60Hz |
Power (W) | 845 | |
Power Consumption (kWh/24h) | 11.6 | |
Vials load | 2ml Vials (pcs) | 28800 |
Size & Weight | Internal (W*D*H) mm | 606×575×1180 |
External (W*D*H) mm | 900×940×1940 | |
Packing (W*D*H) mm | 950×960×2110 | |
Net/Gross weight (kg) | 215/245 | |
Alarm System | High/low temperature | √ |
Power off failure | √ | |
Abnormal voltage | √ | |
Sensor error | √ | |
Filter screen check | √ | |
Controller failure | √ | |
Low battery | √ | |
Condenser malfunction | √ | |
High ambient temperature | √ | |
Door ajar | √ | |
Accessories | Caster | 4 |
Test hole/Diameter | 1/25mm | |
Remote alarm contact | √ | |
USB Port | Y | |
RS232/485 port | Optional | |
Temperature recorder | Optional | |
Freezer racks | Optional | |
CO2 backup system | Optional | |
LN2 backup system | Optional |
The -86℃ ULT freezer is specially designed for a stable ultra low temperature storage condition, to store germs, erythrocytes, leucocytes, viruses and many other biological materials. Installations can be found in research institutes, pharmacy industry, clinical labs, blood banks and laboratories in electronic & chemical plants.